Show simple item record

dc.contributor.advisorFloyd, William A.
dc.contributor.authorJohnson, Brenda M.
dc.date.accessioned2011-10-17T13:53:16Z
dc.date.available2011-10-17T13:53:16Z
dc.date.issued1993-12
dc.identifier.urihttp://digital.library.wisc.edu/1793/54617
dc.description.abstractA modified closed circuit, oxygen dilution method for the measurement of residual volume (RV) was compared to the method described by Wilmore (1969). The major difference in equipment was the substitution of a 7 liter calibration syringe and rubber rebreathing bag for the wet spirometer in the original procedure. Duplicate measurements of RV were made with each method in random order of 90 subjects (45 M,45 F) age 18 to 69 (mean = 31 yrs).en
dc.language.isoen_USen
dc.titleValidation of a modified closed circuit, oxygen dilution residual volume methoden
dc.typeThesisen
thesis.degree.levelMSen
thesis.degree.disciplineAdult Fitness and Cardiac Rehabilitationen


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record